The Anden A77 Digital Dehumidifier Control is a wall-mounted, hardwired controller designed to give indoor cultivators direct, convenient management of relative humidity levels without having to access the dehumidifier unit itself. It connects directly to compatible Anden dehumidifiers, provides a clear digital readout of current relative humidity, and lets you set target RH using one-touch on/off and up/down buttons. Anden backs this controller with a 5-year warranty.
Anden A77 Digital Dehumidifier Control Specifications
The A77 is a wired remote-control accessory for Anden dehumidifiers. It mounts on the wall within the grow space and connects directly to the dehumidifier via a hardwired connection. The specifications below are derived from the canonical product data and manufacturer documentation.
| Specification | Value |
|---|---|
| Brand | Anden |
| Model | A77 |
| Control Type | Hardwired wall-mounted digital controller |
| Display | Digital relative humidity readout (bold display) |
| Interface | On/Off buttons, Up/Down arrows for RH adjustment |
| Weight | 0.5 lb (0.5004 lb) |
| Warranty | 5 years |
| Compatibility | Compatible Anden dehumidifiers (hardwired connection) |
Why Choose the Anden A77 Digital Dehumidifier Control
Managing relative humidity in an indoor grow room involves more than simply running a dehumidifier at a fixed setting. Fluctuating canopy temperatures, plant transpiration rates, and changes in outdoor weather all affect indoor RH levels, which means frequent monitoring and adjustment are part of day-to-day cultivation work. The A77 makes that process more convenient and more precise.
- Remote wall-mount access: Because the A77 is hardwired and wall-mounted, you can check and adjust RH settings from a convenient location in the grow room without navigating to the dehumidifier itself, which is often positioned in a hard-to-reach or tightly packed area of the space.
- Clear digital display: The unit shows relative humidity in a bold digital readout, so readings are immediately legible even in lower-light grow conditions without squinting at a small indicator LED or dial.
- Simple one-touch interface: The on/off button and up/down arrows keep operation straightforward. There is no complex menu system to navigate, which reduces the chance of accidental mis-settings when making quick adjustments mid-grow.
- Hardwired accuracy: Because the A77 connects directly to the dehumidifier rather than relying on wireless communication, it provides reliable, accurate control without the signal dropouts or pairing issues that can affect wireless accessories in metal-lined grow tents or rooms with heavy electromagnetic interference from HID lighting.
- 5-year warranty: Anden includes a 5-year warranty on the A77, reflecting the company’s stated commitment to product dependability in commercial and serious hobbyist cultivation settings.
Best Uses for the Anden A77 Digital Dehumidifier Control
The A77 is an accessory controller, not a standalone dehumidifier. It is most useful in grow environments where the dehumidifier must be positioned away from the primary work or monitoring area, or where centralized environmental control panels are being built out. Consider the A77 in the following situations:
- Multi-room or large single-room grows: When a dehumidifier is tucked into an equipment corner, mounted near the ceiling, or positioned behind racking, a wall-mounted controller at eye level in the main walkway saves time during daily rounds and reduces the risk of disturbing canopy or irrigation infrastructure to reach the unit.
- Late flower and drying stages: Relative humidity management is most critical in weeks 6–9 of flower (to suppress botrytis and powdery mildew) and during hang-drying after harvest. The A77 lets cultivators dial in tighter RH windows during these sensitive periods without repeatedly climbing over equipment to access the dehumidifier directly.
- Commercial and semi-commercial facilities: Facilities running Anden dehumidifiers as part of a broader climate control build-out benefit from having dedicated wall controls at workstation height, keeping monitoring and adjustment consistent with the rest of the environmental control panel.
- Environments where wireless is unreliable: Metal-framed or foil-lined rooms can degrade wireless signal quality. As a hardwired controller, the A77 is unaffected by radio frequency interference from ballasts, HVAC variable frequency drives, or other grow room electronics.
The A77 pairs well with Boveda 2-Way Humidity Packs for integrated humidity management across both active dehumidification and passive buffering during the drying and curing process.
Anden A77 vs Similar Dehumidifier Controllers
The A77 occupies a specific role: it is a wired, dedicated remote-control accessory built for Anden dehumidifiers. It is worth understanding what it is and is not compared to other humidity management approaches:
A77 vs wireless humidity controllers: Standalone programmable humidity controllers (such as digital RH switches that use a probe and a relay to cycle a dehumidifier’s power) offer broader compatibility — they can work with virtually any dehumidifier. However, they add a probe, a relay, and a cable run that may introduce measurement lag or calibration drift. The A77, by contrast, uses the dehumidifier’s own internal sensor and communicates directly over a hardwired connection, so the humidity reading displayed is the reading the dehumidifier is acting on — there is no separate sensor to calibrate or recalibrate.
A77 vs accessing the dehumidifier directly: If your Anden dehumidifier is accessible and at a convenient height, the A77 is optional. Its value is specifically in environments where direct access is inconvenient. If you run an Anden dehumidifier in a grow room where the unit is always within arm’s reach during normal operations, the A77 adds convenience but is not operationally necessary.
A77 vs smart/app-connected controllers: The A77 does not offer remote monitoring via smartphone or app integration. It is a physical wall panel only. Growers who need remote monitoring from outside the grow room would need a separate data-logging device or an Anden model with built-in connectivity. The A77 is a point-of-presence control panel, not a remote-access solution.
If you are also managing condensate removal from your dehumidifier, the Ideal-Air Pro Series Dehumidifier Replacement Condensate Pump is a related accessory worth reviewing for your drainage setup.
Compatibility
The Anden A77 is designed to connect directly to compatible Anden dehumidifier models via a hardwired connection. It is not a universal controller and is not compatible with non-Anden equipment. The A77 operates as an extension of the dehumidifier’s own control system rather than as an external override device, which is why the RH reading shown on the A77’s display reflects the dehumidifier’s own sensor rather than an independent probe.
When specifying the A77 for your grow room setup, confirm the following:
- Your Anden dehumidifier model includes a port or connector for the A77 hardwired control interface. Consult Anden’s product documentation or contact Anden directly to confirm compatibility with your specific dehumidifier model number.
- The wall-mount location you choose for the A77 is within the cable run length supported by your dehumidifier model’s wiring harness. If your installation requires a longer run, consult Anden for any extension options.
- The A77 is intended for indoor use in controlled environments such as grow rooms and indoor cultivation facilities. It should not be installed in locations exposed to direct water spray, standing water, or outdoor weather conditions.
For air circulation in the same grow room, review the Active Air 18″ HD Pedestal Fan as a complement to your dehumidifier and climate control setup.
Usage Guidelines
The A77 controls relative humidity by acting as the interface between you and your Anden dehumidifier. Here is how to use it effectively during a standard cultivation cycle:
Setting target RH by growth stage: Relative humidity targets vary considerably across the plant lifecycle. Vegetative growth typically tolerates a wider RH range (45–70% RH), while mid-to-late flower requires tighter management (40–50% RH) to reduce disease pressure. Use the A77’s up/down arrows to dial in the appropriate setpoint for the current stage. The digital display shows the current ambient RH so you can see both the setpoint and the actual reading in normal operation.
Energy management: The A77 includes an on/off switch that lets you disable the dehumidifier from the wall panel without unplugging the unit or navigating to it physically. During the lights-off period, temperature drops typically reduce transpiration and may reduce the dehumidifier duty cycle. Monitoring RH patterns over several days and adjusting the setpoint accordingly — rather than leaving it at a fixed setting throughout the entire grow — can reduce energy consumption without compromising humidity targets.
Checking readings: Because the A77 displays RH in bold on its digital screen, a quick visual check during walk-throughs is sufficient for routine monitoring. If the reading appears inconsistent with plant appearance or other sensors in the room, verify that the dehumidifier’s own sensor is clean and unobstructed, as the A77 reflects that sensor’s output directly.
How to Install the Anden A77
Installation of the A77 involves mounting the wall panel and connecting it to the dehumidifier’s hardwired control port. The steps below reflect the general installation process for a hardwired wall-mounted accessory controller; consult the documentation included with your specific Anden dehumidifier for the exact wiring connector type and cable routing specifications.
- Before beginning, power off the Anden dehumidifier and unplug it from the wall outlet. Do not work on the wiring harness with the dehumidifier energized.
- Select the wall-mount location for the A77. Choose a position that is at a convenient working height (approximately eye level), within the cable run distance supported by your dehumidifier model, and away from direct water sources or irrigation spray zones.
- Mount the A77 bracket or backplate to the wall using appropriate fasteners for the wall material (drywall anchors, masonry fasteners, or wood screws as applicable). Ensure the mount is level and secure.
- Route the hardwired connection cable from the A77 to the dehumidifier, following safe cable management practices — avoid running the cable across walkways or through water accumulation areas. Use cable ties or conduit as needed.
- Connect the cable to the designated control port on the Anden dehumidifier. Refer to the connector diagram in the dehumidifier’s installation manual to confirm correct orientation and seating.
- Snap or attach the A77 control panel to the mounted bracket. Verify that all connections are secure and the panel is properly seated.
- Restore power to the dehumidifier. The A77 display should activate and show the current relative humidity reading. Press the on/off and up/down buttons to confirm the interface is responsive.
- Set the initial RH target appropriate for your current growth stage using the up/down arrows. Verify that the dehumidifier responds to the setpoint by running a brief operational check.











Reviews