The Autopilot PX2 Advanced Lighting Controller centralizes photoperiod scheduling and output control for up to 512 fixtures across two independently operated zones. Built for commercial and serious hobby grow operations running Phantom HID, Core HID, or PHOTOBIO LED fixtures, the PX2 replaces traditional lighting contactors, eliminates inrush current, and delivers sunrise/sunset simulation, auto-dimming, and emergency shutdown — all with a single unit and universal 100–240V input.
Autopilot PX2 Specifications
Full physical and electrical specifications sourced from the cultivate_supply canonical listing (SKU APDPX2), hortamericas.com physical data, and the manufacturer description text.
| Specification | Value | Notes |
|---|---|---|
| SKU | APDPX2 | Autopilot / Hydrofarm |
| Total Fixture Capacity | 512 (digital HID) / 100 (analog LED) | 256 digital HID per zone; 50 analog LED per zone |
| Independently Controlled Zones | 2 | Each zone runs its own photoperiod, PPF, and thermal thresholds |
| Digital HID Per Zone | 256 | Via Phantom or Core HID data cable (20-ft RF-shielded included) |
| Analog LED Per Zone | 50 | Via PHOTOBIO LED data cable (20-ft RF-shielded included) |
| Input Voltage | 100–240V, 50/60 Hz | Universal — compatible with North American and international mains |
| Amperage | 0.3 A (controller only) | Fixtures draw current independently; this is the controller draw |
| Built-in Battery Backup | Yes | Retains all programming and schedules through power interruptions |
| Data Connector Type | Locking mini 3P IP65 female connectors | Moisture-resistant; RF-shielded cables reduce EMI |
| Weight (unboxed) | 3.75 lb (1.70 kg) | |
| Dimensions (L × W × H) | 6.42 × 13.07 × 5.00 in | Unboxed controller unit |
| Compatible Fixtures | Phantom HID (controllable), Core HID (controllable), PHOTOBIO LED | All Hydrofarm-family brands |
Why Choose the Autopilot PX2
The PX2 addresses a real operational problem in multi-light grow facilities: you cannot efficiently manage hundreds of HID or LED fixtures with individual timers, contactors, and manual dimmer settings. The PX2 consolidates that work into a single device with zone-level precision. Here is what makes it the right controller for high-fixture-count environments:
- Dual-zone independent control at scale. Each zone carries its own photoperiod schedule, PPF output target, temperature thresholds, and sunrise/sunset ramp profile. Zone A can be on a 18/6 vegetative cycle while Zone B runs a 12/12 bloom cycle — simultaneously, from one controller. This is not a toggle between modes; both zones operate fully independently at all times.
- 512-fixture maximum (digital HID mode). With 256 digital HID fixtures per zone, the PX2 can address an entire large-scale commercial room. By comparison, the Grower’s Choice Master Controller caps at 200 fixtures total. For operations with more than 200 HID lights, the PX2 is the direct path to centralized control without adding a second controller.
- Universal voltage input eliminates facility-specific SKUs. The 100–240V, 50/60 Hz power adapter means one controller SKU covers North American 120V installations, 240V single-phase rooms, and international facilities. No voltage selector switch, no step-down transformer needed.
- Sunrise and sunset simulation per zone. Gradual ramp-up at the start of the photoperiod and ramp-down at the end mimic natural light transitions. This is relevant for stress reduction in some cultivars and is particularly useful during propagation and early veg where abrupt light-on events can stress cuttings.
- Built-in battery backup. All zone schedules, PPF targets, temperature thresholds, and timing data are retained in battery-backed memory. A brief power interruption does not reset your crop-day counter or require manual reprogramming. For operations where a clock reset could trigger a premature dark period, this is a material protection.
- Eliminates inrush current and replaces contactors. HID ballasts draw a spike of current at ignition (inrush) that degrades contactors over time and can trip breakers if multiple fixtures start simultaneously. The PX2 manages startup sequencing across its connected fixtures, distributing the inrush load and extending both ballast and electrical infrastructure service life.
- RF-shielded locking cables. Grow rooms generate electromagnetic interference from fans, pumps, ballasts, and inverters. Unshielded signal cables in this environment pick up noise that causes intermittent communication drops. The locking mini 3P IP65 connectors and RF-shielded data cables maintain signal integrity regardless of what other equipment is running in the same space.
Best Uses for the Autopilot PX2
The PX2 is a fixture-management controller, not a simple timer. Its dual-zone architecture and high fixture capacity make it useful in specific grow configurations that simpler controllers cannot handle cleanly. The following scenarios are drawn directly from the manufacturer’s use-case documentation and grower-reported applications:
- Checkerboarding different lighting technologies in one room. Running HPS and CMH fixtures in alternating rows is a well-established technique for blending spectral output across the canopy. With the PX2, each technology occupies its own zone — Zone A controls the HPS rows, Zone B controls the CMH rows — allowing independent output adjustments when one technology needs to be dimmed independently of the other. The same logic applies to HPS/LED hybrid rooms or CMH/LED configurations.
- Energy management through zone-level dimming. Two identical fixture sets can be split across zones and run at different output percentages during overlapping phases of the crop cycle. For example, a facility running double-ended HPS at 1000W in both zones during peak flower can drop Zone B to 600W equivalent during early transition without affecting Zone A’s uniformity. The energy savings compound across an entire harvest cycle.
- Multi-room commercial grows with centralized control. A single PX2 can address up to 512 HID fixtures across two rooms from one mounted location, eliminating the need for individual room controllers and reducing the number of maintenance points per facility. For operations expanding from single-room to multi-room, the PX2 provides a scalable control layer without requiring a complete infrastructure rework.
- Perimeter vs. interior uniformity management. Fixtures at the perimeter of a grow space often receive different reflectance and heat exposure than fixtures over the interior canopy. Placing perimeter fixtures on one PX2 zone and interior fixtures on the other lets growers independently tune output to compensate for edge-uniformity losses — a common issue in rooms taller than 12 feet or with sub-optimal reflective surfaces.
- Alternating row crop management for staggered harvests. Some commercial operations run perpetual harvests with alternating rows at different growth stages. Zone A can run a 12/12 flower schedule while Zone B runs 18/6 veg on the adjacent row set, both managed from the same PX2 without any external timer intervention.
- Controlled restrike sequencing for sealed rooms. In sealed CO2-enriched rooms, high restart frequencies on HID fixtures create heat spikes that disturb CO2 management. The PX2’s configurable restrike delay prevents hot restarts by enforcing a cool-down window before relighting, protecting lamp life and keeping thermal management predictable.
Autopilot PX2 vs Grower’s Choice Master Controller
The two most directly comparable centralized multi-zone lighting controllers for indoor grows are the Autopilot PX2 ($389.94) and the Grower’s Choice Master Controller (~$499.00 MSRP). Both offer dual-zone operation, photoperiod scheduling, thermal auto-dimming, and sunrise/sunset simulation. The differences are meaningful at scale:
| Feature | Autopilot PX2 | Grower’s Choice Master Controller |
|---|---|---|
| Price (MSRP) | $389.94 | ~$499.00 |
| Total Fixture Capacity | 512 (digital HID) / 100 (analog LED) | 200 (100 per zone / 2 channels) |
| Zones | 2 (fully independent) | 2 (dual channel) |
| Compatible Fixtures | Phantom HID, Core HID, PHOTOBIO LED | GC-315 CMH, GC-630NS CMH, GC-1000 DE, ROI-E Series LED |
| Mixed Analog/Digital Zones | Yes — each zone configurable independently | Not documented |
| Input Voltage | 100–240V universal | 120V (North America) |
| Battery Backup | Built-in | Not documented |
| Inrush Current Management | Yes — replaces lighting contactors | Not documented |
| Cable Shielding | RF-shielded locking data cables | Standard cables |
Summary: The PX2 offers more than double the fixture capacity of the Grower’s Choice Master at a lower price point. The trade-off is fixture compatibility: the GC Master only works with Grower’s Choice fixtures, while the PX2 is restricted to Phantom, Core HID, and PHOTOBIO LED. If your facility is already built on Phantom or PHOTOBIO fixtures, or you are planning to scale into one of those brands, the PX2 is the stronger purchase at any room size.
Compatibility & Operating Range
The PX2 is a digital control system, not a power relay. It does not switch mains current to the fixtures directly; it sends control signals to compatible fixture ballasts or drivers via data cables. This means compatibility is determined by the fixture’s data protocol, not by its wattage or phase configuration.
Compatible fixture lines:
- Phantom HID (controllable models): Phantom digital HID ballasts that accept the locking mini 3P M-RJ 6P data signal. The PX2 ships with two 20-foot RF-shielded Phantom data cables. Daisy-chaining allows up to 256 Phantom fixtures per zone (512 total across both zones).
- Core HID (controllable models): Core-brand digital HID fixtures using the same Phantom-compatible data protocol. Verify the specific Core ballast model accepts the PX2 data cable before purchasing.
- PHOTOBIO LED (all current models): PHOTOBIO LED fixtures use a separate analog control protocol. The PX2 ships with two 20-foot RF-shielded PHOTOBIO data cables (locking mini 3P M-2P M). Up to 50 PHOTOBIO LED fixtures can be addressed per zone. If you already run PHOTOBIO fixtures such as the PHOTOBIO•TX or PHOTOBIO•VP, these connect natively without adapters.
Zone mode flexibility: Both zones can run in digital HID mode (512 total HID capacity), both can run in analog LED mode (100 total LED capacity), or one zone can run digital while the other runs analog. This means a mixed HID/LED room with up to 256 HID + 50 LED fixtures can be managed by a single PX2 — each technology type on its own zone, fully independently scheduled.
Electrical operating range: 100–240V, 50/60 Hz. The controller itself draws 0.3 A from mains. The fixtures it controls draw current independently from their own circuits; the PX2 does not pass fixture load current through its own wiring. This separation is important for circuit planning: size your lighting circuits for the fixtures, not for the controller.
Temperature sensors: The two included 50-foot temperature probes are rated for standard indoor grow-room operating conditions. Place one probe per zone at canopy height in a shaded location (not directly under a fixture) for accurate ambient temperature readings. The auto-dim and shutdown thresholds the PX2 uses are based on these probe readings, so probe placement directly affects when the thermal-protection features activate.
Not compatible with: Fluence, Gavita, Philips GreenPower, or other third-party LED and HID systems. The PX2 uses Hydrofarm-proprietary data protocols. If your facility uses a mix of Phantom and third-party fixtures, the PX2 will control only the Phantom/PHOTOBIO units; third-party fixtures require separate control infrastructure. For a more universal option that works across lighting brands, consider dedicated environmental control platforms designed for 0–10V analog dimming.
Good companions for a complete climate management system include an Active Air HD 18" Pedestal Fan to maintain air circulation that keeps temperature probe readings stable, and humidity monitoring solutions like Boveda 2-Way Humidity Packs for curing and storage areas adjacent to the controlled grow space.
Usage Guidelines
The PX2 manages three core operational parameters per zone: photoperiod timing, photosynthetic photon flux (PPF) output, and temperature-based responses. Understanding how these interact prevents scheduling errors and protects your crop.
Photoperiod scheduling: Each zone runs its own independent light-on / light-off schedule. Set the clock time for lights-on and lights-off for each zone separately. The PX2’s real-time clock retains the schedule in battery-backed memory, so a brief power outage will not shift the photoperiod. For critical stages — particularly the dark period during 12/12 flowering — verify the clock is set correctly after any extended power outage or battery replacement.
PPF (Photosynthetic Photon Flux) control: The PX2 allows you to set the output level for each zone by wattage or percentage of maximum. This maps to the dimming range of the connected fixtures — for digital HID, dimming typically runs from 100% down to 50% depending on the ballast model. For PHOTOBIO LED, the analog signal covers the full 0–100% dimming range. During seedling and early propagation stages, reducing PPF to 50–60% of maximum prevents light-induced stress without changing the photoperiod.
Auto-dimming thresholds: Set a temperature set point per zone (typically 80–85°F / 27–29°C for HID rooms). When the temperature probe reads above this threshold, the PX2 automatically reduces fixture output for that zone to the configured dim level. This protects the canopy during HVAC failures or peak-load periods without requiring manual intervention. The set point and dim level are configured independently per zone.
Emergency shutdown threshold: A second, higher temperature threshold can trigger a complete lights-off event for the zone. Set this 5–10°F above the auto-dim set point. This is a last-resort protection for extreme HVAC failures; the zone remains dark until the temperature drops back below the threshold and is manually re-enabled. Do not set the emergency shutdown threshold below the auto-dim threshold, or the controller may oscillate between dimming and shutdown.
Restrike delay configuration: HID lamps require a cool-down period after being extinguished before they can re-ignite. Attempting a hot restart damages the arc tube and shortens lamp life. Set the restrike delay to at least 10–15 minutes for most HID lamp types (consult the lamp manufacturer’s data sheet for the specific cool-down minimum). The PX2 enforces this delay automatically after any lights-off event, whether manual or triggered by temperature protection.
Sunrise/sunset simulation: Each zone can be configured with a gradual ramp-up period at lights-on and a ramp-down at lights-off. Common configurations are 15–30 minute ramps at each end. This feature reduces abrupt light transitions that can stress plants and is particularly useful in propagation rooms and during the first week of the 12/12 transition when light stress response is elevated.
Zone mode assignment: Before connecting fixtures, determine whether each zone will run in digital HID mode or analog LED mode. This determines which data cable set to use. A zone assigned to digital HID mode uses the locking mini 3P M-RJ 6P Phantom cables; a zone assigned to analog LED mode uses the locking mini 3P M-2P M PHOTOBIO cables. Mixing cable types on a single zone is not supported and will cause communication errors.
How to Install the Autopilot PX2
Installation involves physically mounting the controller, running the data cables to each fixture, placing the temperature probes, connecting power, and configuring zones via the LED readout interface. Plan the cable routing before drilling or mounting anything — the included data cables are 20 feet long, which sets the maximum distance between the controller and the most distant fixture in each zone without extension cables.
- Choose a mounting location. The PX2 should be mounted on a wall or panel outside the main crop canopy area, in a location accessible for programming and maintenance. Keep it away from direct water spray, irrigation lines, and high-heat zones. Use the two included mounting screws into a solid backing surface (wall stud or panel rail). The controller unit itself weighs 3.75 lb — drywall anchors are acceptable for a flat-mount horizontal surface but not recommended for overhead installation.
- Plan and route your data cables. Identify how many fixtures will be on each zone and which data cable type each zone requires (Phantom/Core HID cables vs. PHOTOBIO LED cables). Route the 20-foot RF-shielded data cables from the controller to the first fixture in each zone’s daisy-chain. Cable runs should be kept away from high-voltage wiring and ballast enclosures wherever possible to minimize any EMI pick-up even through shielded cables.
- Connect the temperature probes. Plug each 50-foot white temperature probe into the corresponding zone input on the PX2. Run the probes to canopy level in their respective zones. Mount the probe tip in a shaded position at mid-canopy height — zip-tie or clip it to a horizontal wire or trellis support, not directly to a pot or substrate (which would read substrate temperature, not air temperature). The probe length is 50 feet, giving substantial flexibility in placement.
- Connect the data cables to fixtures. Starting from the first fixture closest to the controller, connect the locking data cable from the PX2 zone output to the fixture’s data input. If daisy-chaining additional fixtures, connect them in sequence using the fixture’s data pass-through output to the next fixture’s data input. Lock each connector by rotating the collar after seating. Repeat for both zones.
- Connect the power adapter. Plug the included 5-foot 100–240V power adapter into the PX2’s power input jack and then into a grounded outlet. The controller’s LED readout should illuminate, indicating it is receiving power. Do not power on the controller before all data cables and temperature probes are connected, as some firmware revisions will register missing probes as a fault condition.
- Configure Zone 1 mode and schedule. Use the LED readout interface to navigate to Zone 1 settings. Set the zone mode (digital HID or analog LED), enter the lights-on and lights-off times for your crop’s photoperiod, set the PPF output level (100% unless you have a reason to start at a lower level), and configure the auto-dim temperature threshold and restrike delay. The instruction manual included with the PX2 provides the full button sequence for each parameter.
- Configure Zone 2 mode and schedule. Repeat the configuration process for Zone 2, which may have a different photoperiod, PPF level, and temperature threshold than Zone 1 if you are running different crop stages or lighting technologies across the two zones.
- Verify communication with each fixture. Power on the connected fixtures via the PX2’s manual override or by allowing the scheduled lights-on time to arrive. Verify that each fixture responds to the PX2’s commands (lights on, dim to a specific level). If fixtures are not responding, check the data cable locking collars, verify zone mode matches the cable type in use, and confirm the fixture models are on the PX2-compatible fixture list.
- Log the configuration. Record zone settings, probe placement locations, cable routing, and connected fixture count in a maintenance log. This simplifies troubleshooting and lets other operators reconstruct the setup without accessing the programming interface during a crop-critical period.








Reviews
There are no reviews yet.