The Gavita Replacement Kit for 1000W Lamp and Reflector pairs the Gavita Pro Plus 1000W EL double-ended 400V HPS lamp with a HR96 reflector, giving Gavita fixture owners a single-purchase solution for replacing the two core components that affect output most. The double-ended lamp is engineered specifically for high-frequency electronic ballasts and is restricted to Gavita Pro series fixtures.
Gavita Replacement Kit Specifications
Key technical specifications for the Gavita Pro Plus 1000W EL double-ended lamp and HR96 reflector kit. All values are derived from the manufacturer product description and supplier data.
| Specification | Value |
|---|---|
| Product Type | Double-Ended (DE) HPS Lamp + Reflector Kit |
| Wattage | 1000W |
| Lamp Voltage | 400V |
| Lamp Technology | High-Pressure Sodium (HPS), Double-Ended EL |
| Ballast Requirement | High-frequency electronic ballast (Gavita Pro series) |
| Lamp Envelope | Quartz glass jacket |
| Reflector Included | HR96 reflector |
| Fixture Compatibility | Gavita fixtures only |
| Supplier SKU | HGC906026 |
| Brand | Gavita |
Why Choose the Gavita Replacement Kit for 1000W Lamp and Reflector
When a lamp reaches the end of its rated life or a reflector becomes fouled or damaged, replacing both components at the same time restores the fixture to its original output level without the guesswork of sourcing parts separately. The Gavita Replacement Kit for 1000W Lamp and Reflector is assembled for exactly this purpose: one part number covers the lamp and the HR96 reflector together, keeping your Gavita Pro series fixture running at spec.
The Gavita Pro Plus 1000W EL lamp is a double-ended design. Unlike single-ended HPS lamps, a DE lamp has electrical contacts at both ends of the arc tube, which eliminates the need for a frame wire running through the outer envelope. That wire, present in single-ended lamps, causes a light-blocking shadow and is a mechanical point of failure over time. Removing it allows the full arc to radiate without internal obstruction and reduces mechanical stress inside the outer jacket during operation.
The lamp is rated for high-frequency electronic ballasts operating at 400V. This is a narrower operating window than broad-spec lamps, but the tradeoff is that the lamp is tuned to the ballast’s output characteristics — the arc is more stable, flicker is reduced, and lamp life is consistent. The warranty is explicitly tied to use with a Gavita Pro series ballast, which keeps the electrical environment predictable and within the manufacturer’s tested range.
The included HR96 reflector completes the kit. When a reflector interior becomes oxidized, scratched, or coated with dust and condensation residue, it scatters light instead of directing it downward to the canopy. Pairing a new lamp with an old reflector leaves output compromised. The kit addresses both variables together.
- Double-ended lamp architecture: contacts at each end of the arc tube eliminate the internal frame wire, allowing unobstructed light output across the full arc length.
- Tuned for high-frequency electronic ballasts at 400V: the lamp is designed for the electrical conditions produced by Gavita Pro series ballasts, not generic magnetic or hybrid drivers.
- Quartz glass outer jacket: quartz withstands the operating temperatures of a 1000W HPS arc and provides a clean, UV-transmissive envelope — but it is oil-sensitive; bare-hand contact leaves residue that can create hot spots and shorten lamp life.
- HR96 reflector included: the kit restores both light source and light-directing components, rather than requiring separate purchases.
- Gavita Pro series warranty compliance: warranty coverage applies when operated with a Gavita Pro series ballast, making this kit the correct replacement path for owners of Gavita fixtures already running that ballast family.
Best Uses for the Gavita Replacement Kit for 1000W Lamp and Reflector
This kit is a targeted replacement product. Its applications are directly tied to the Gavita Pro series HPS fixture ecosystem.
- Scheduled lamp replacement in commercial grow rooms: HPS lamps lose a measurable percentage of output each cycle even before visible failure. Growers running Gavita Pro 1000W DE fixtures on a replacement schedule — typically every 10,000–12,000 hours or at the start of a new crop cycle — use this kit to restore the fixture to original light output levels. Replacing the reflector at the same interval removes oxidation and surface degradation that accumulates over time.
- Corrective replacement after lamp failure: when a lamp fails mid-cycle, getting the fixture back into production quickly matters. This kit provides both the lamp and reflector in a single order, reducing the number of parts that need to be sourced and tracked. Because the lamp is Gavita-specific, it is not interchangeable with other brands’ DE lamps in this fixture.
- Reflector-only refresh with lamp swap: growers who notice reduced light uniformity, increased shadowing at canopy edges, or visible surface damage on the HR96 reflector can use this kit to address both issues without disassembling the fixture twice. The kit is also appropriate when a reflector is replaced due to physical damage — a new lamp installed into a compromised reflector would not recover full canopy coverage.
- Gavita Pro series fixture maintenance in flowering stages: the 1000W HPS spectrum is most commonly used during flowering phases where high-intensity output and red-spectrum emphasis support dense bud development. Maintaining a fresh lamp and reflector during a flowering cycle keeps photon delivery consistent from the first week through harvest.
- Facility standardization: operations running multiple Gavita 1000W DE fixtures can stock this kit as a single SKU that covers both consumable components, simplifying purchasing and inventory management compared to maintaining separate lamp and reflector part numbers.
Compatibility
The Gavita Pro Plus 1000W EL double-ended lamp in this kit is designed exclusively for use with Gavita fixtures and Gavita Pro series ballasts. The manufacturer explicitly states that the warranty applies only when the lamp is operated with a Gavita Pro series ballast. This is not a universal-fit DE lamp.
The 400V operating voltage and high-frequency electronic ballast requirement mean this lamp will not perform correctly — and may fail early or damage the ballast — if run on a magnetic ballast, a non-Gavita electronic ballast, or a hybrid ballast that is not rated for high-frequency DE operation. Growers using Lumatek, Dimlux, or other third-party ballasts should consult those manufacturers’ lamp compatibility lists before substituting this lamp.
The HR96 reflector included in the kit is a Gavita-designed reflector for their Pro series 1000W DE fixtures. It is not a universal reflector. Dimensions and mounting hardware are matched to Gavita fixture housings.
If you are running a Gavita Pro series LED fixture such as the Gavita Pro 1700e LED, this HPS lamp kit does not apply — LED fixtures use a completely different light engine and have no serviceable lamp or HPS-style reflector component.
For growers who need supplemental T5 propagation lighting alongside their HPS flower rooms, the T5 Designer 4ft 4-Tube Fixture with Bulbs is a separate propagation tool that operates independently of any HPS ballast or fixture.
Usage Guidelines
Correct handling and installation of the Gavita 1000W DE lamp is important for both lamp performance and safety. The following guidelines apply to the lamp in this kit.
Do not handle the lamp with bare hands. The outer jacket of a double-ended HPS lamp is made from quartz glass. Quartz is sensitive to the oils present on skin. When a fingerprint or palm print is left on the quartz surface, the oil creates a localized hot spot during operation as the lamp reaches operating temperature. Over time, this can cause the quartz to crack or fail, and in some cases can cause premature lamp failure or a hazardous rupture. Always handle the lamp with clean cotton gloves or hold it by the end caps only.
If the lamp has been touched with bare hands: clean the affected area gently with isopropyl alcohol on a lint-free cloth before operating the lamp. Allow the surface to dry completely before powering on the fixture.
Ballast compatibility: confirm the fixture’s ballast is a Gavita Pro series high-frequency electronic ballast rated for 1000W DE operation at 400V before installing this lamp. Operating the lamp on an incompatible ballast voids the warranty and can damage both the lamp and the ballast.
Lamp orientation: double-ended lamps are designed to operate horizontally in the fixture. Vertical installation can cause uneven thermal loading and arc tube deformation over time. Follow the Gavita fixture manual for the correct lamp orientation in your specific model.
Warm-up time: HPS lamps require several minutes to reach full output after ignition. Avoid cycling the lamp on and off repeatedly in a short period — frequent hot restarts shorten lamp life. If the lamp extinguishes during operation, allow it to cool for 10–15 minutes before restarting.
Reflector cleaning: the HR96 reflector should be kept free of dust and moisture. Wipe the interior surface with a dry lint-free cloth when the fixture is powered off and fully cooled. Avoid abrasive cleaners or rough cloths that can scratch the reflective surface.
How to Install the Gavita 1000W Lamp and Reflector
Follow these steps when replacing the lamp and reflector in a Gavita Pro series 1000W DE fixture. Power off and allow the fixture to cool completely before beginning — HPS lamps and reflectors retain significant heat after operation.
- Power down and cool: switch off the ballast and disconnect the fixture from power. Wait at least 30 minutes after the last lamp operation to allow the lamp, reflector, and fixture housing to cool to a safe handling temperature.
- Remove the old reflector: release any retaining clips, screws, or latches securing the HR96 reflector to the fixture housing. Lower the reflector carefully — it may still be warm even after cooling time. Set it aside on a clean, flat surface.
- Remove the old lamp: put on clean cotton gloves. Grasp the old lamp by its end caps and slide or twist it free from the lamp holders at each end of the fixture, following the release mechanism specific to your Gavita fixture model. Place the old lamp in the packaging from the new kit for safe disposal.
- Inspect the lamp holders: before installing the new lamp, visually check both lamp holders for corrosion, cracking, or loose contacts. A damaged lamp holder can cause poor electrical contact, arcing, or premature lamp failure. Do not install the new lamp into a damaged holder.
- Install the new lamp: with cotton gloves still on, remove the new Gavita Pro Plus 1000W EL lamp from its packaging. Do not touch the quartz glass body with bare skin. Align the end cap contacts with the lamp holders and seat the lamp firmly at both ends. Confirm the lamp is fully engaged in both holders before proceeding.
- Install the new HR96 reflector: position the new reflector over the lamp and engage any retaining clips, screws, or latches. Confirm the reflector is seated flat and secure — an unsecured reflector can shift during operation and alter light distribution.
- Reconnect power and test: reconnect the fixture to power and the ballast. Switch the ballast on and observe the lamp ignition. The lamp will take several minutes to reach full brightness. Verify there are no unusual sounds, flickering after warm-up, or visible arc instability. If the lamp does not ignite or exhibits abnormal behavior, power down immediately and check all connections before troubleshooting further.
Sources & Further Reading
Technical specifications and product details for this kit are drawn from the manufacturer product description. For complete fixture compatibility information, lamp installation guides, and the Gavita Pro series ballast documentation, consult the official Gavita website.







Reviews
There are no reviews yet.