The Titan Controls Helios 18 is a 12-outlet, 240-volt lighting controller designed for large-scale HID grow operations. It can run twelve lights simultaneously and uses industrial-grade ballast relays to handle the demands of high-wattage HPS and MH lamps. Dual trigger cord inputs let you split your room across two independent timer schedules without adding a second controller, and a removable front panel makes hardwiring into your facility’s power system straightforward.
Titan Controls Helios 18 Specifications
All specifications below are drawn directly from the manufacturer product data for the Helios 18 (SKU 702843). The controller is rated for 240-volt service at 60 Hz and can deliver up to 12,000 watts of combined output power across its twelve outlets.
| Specification | Value |
|---|---|
| Brand | Titan Controls |
| Model | Helios 18 |
| Number of Outlets | 12 |
| Operating Voltage | 240 V / 60 Hz |
| Input Power | 80 Amps |
| Output Power | 60 Amps |
| Maximum Wattage | 12,000 W |
| Trigger Cord Sets | Dual (2 independent schedules) |
| Outlet Compatibility | Universal — accepts 120 V or 240 V power cords |
| Relay Type | Industrial-grade ballast relays |
| Enclosure | 20-gauge powder-coated steel, removable front panel |
Why Choose the Titan Controls Helios 18
The Helios 18 is built around the practical demands of running multiple HID lights from a single power distribution point. Here is what distinguishes it from lighter-duty controllers in the same category:
- Industrial-grade ballast relays: Titan Controls describes the Helios series as the only lighting controllers featuring industrial-grade ballast relays. This matters because the inrush current from HID ballasts at startup is significantly higher than running current, and consumer-grade relays can fail or weld shut over time. Industrial relays are rated for this cycling load.
- Dual trigger cord sets for split scheduling: Most 12-outlet controllers accept a single trigger cord from one timer. The Helios 18 includes two trigger cord inputs, so a grower can divide the 12 outlets into two groups and run them on separate timers. This is useful for staggered lighting in large rooms or facilities where not all zones run the same photoperiod.
- Universal outlets for wiring flexibility: The outlets accept both 120 V and 240 V lamp cords. This means you are not locked to a single ballast plug type and can mix ballasts with different cord configurations in the same room, with the controller itself powered at 240 V.
- Removable front panel for clean installation: Hardwiring a controller into a facility’s power system is easier when you can fully expose the terminal block. The removable front panel allows an electrician to complete the wiring without working around a fixed enclosure face.
- Durable steel enclosure: The 20-gauge powder-coated steel body resists the humidity and heat present in active grow rooms. A steel enclosure also reduces the risk of fire spread compared to plastic housings in environments where ballasts generate sustained heat.
Best Uses for the Titan Controls Helios 18
The Helios 18 is sized for operations running ten to twelve HID lights from a single 240-volt circuit or sub-panel feed. Common deployments include:
- Large commercial grow rooms: A 12-light setup typically covers 1,000–1,200 square feet of canopy with 1,000-watt HPS or MH lamps. The Helios 18 consolidates all outlet and trigger wiring into a single enclosure, reducing the number of distribution points an operator has to manage.
- Rooms with two distinct lighting zones: The dual trigger cord inputs allow a single controller to serve two separate timed zones — for example, a veg side and a flower side sharing the same controller but running different photoperiods. This eliminates the cost of a second controller for split-schedule rooms.
- Facilities requiring hardwired power distribution: The removable front panel and 240-volt input make the Helios 18 suitable for rooms where power is delivered via hardwired sub-panel rather than plugged outlets. An electrician can land the feed wires cleanly without the controller being in the way.
- Retrofits alongside existing timer infrastructure: Because the controller is triggered by an external timer’s trigger cord rather than having a built-in clock, it integrates with any timer brand a grower already owns. If you are upgrading from a smaller controller, your existing timers carry over. If you are also looking for a quality T5 fixture to pair with this controller for propagation or mother plant lighting, see the T5 Designer 4ft 4-tube fixture with bulbs.
- HID-based grows pairing with high-output LED infrastructure: In mixed-technology rooms where some zones have transitioned to LED and others still run HID, the Helios 18 handles the HID side. For the LED zones, the Gavita Pro 1700e LED is a common pairing in commercial facilities.
Titan Controls Helios 18 vs Similar Products
The Helios 18 sits in the high-capacity end of HID lighting controllers. When evaluating it against smaller controllers or alternative brands, the following comparisons are relevant based on the product’s stated specifications:
Helios 18 (12 outlets, dual trigger) vs. 8-outlet controllers: Controllers in the 8-outlet class (such as the Titan Helios 12) share the same enclosure style and relay technology but top out at eight lights. If your room runs exactly eight or fewer lights, the smaller model costs less and wastes no capacity. The Helios 18 is only warranted when you need ten to twelve outlets or when the dual-trigger scheduling is a meaningful operational requirement.
Helios 18 vs. basic relay controllers without industrial relays: Lower-cost controllers often use consumer-grade relays that are not rated for the high inrush currents of HID ballasts cycling on and off daily over years of operation. Titan Controls specifically distinguishes the Helios series on industrial-grade relays. If relay longevity and reliability in high-cycle commercial environments are priorities, this distinction matters more than price difference.
Helios 18 vs. digital environmental controllers: Controllers like the Titan Atlas series add temperature, humidity, and CO2 sensing in addition to switching. The Helios 18 is a pure power-distribution and switching device — it does not measure environment or respond to sensor inputs. For rooms where timed switching is all that is needed, the Helios 18 is simpler and less expensive than an environmental controller. For rooms that need responsive control based on temperature or humidity, a digital controller would be the appropriate choice.
Compatibility
The Helios 18 is designed to work with any HID lighting equipment that operates on standard North American power. Key compatibility points drawn from the manufacturer description:
- HID lamp types: The controller is designed for HID lights — high-pressure sodium (HPS), metal halide (MH), and ceramic metal halide (CMH/CDM) ballasts. It is not intended for use with LED drivers or fluorescent ballasts, which have different load characteristics.
- Input voltage: The controller requires a 240-volt, 60 Hz supply. This is standard on 240V dedicated circuits or sub-panel feeds common in commercial grow facilities and purpose-built agricultural spaces.
- Outlet cord types: The universal outlets accept both 120-volt and 240-volt lamp power cords. This means ballasts with NEMA 5-15, NEMA 6-15, and standard 240V cord configurations can plug directly into the controller without adapters.
- Timer/controller compatibility: The dual trigger cord inputs accept standard trigger cord signals from any compatible grow room timer. No proprietary timer is required — the controller works with any timer that outputs a standard 120V or 240V trigger signal via cord.
- Installation type: The removable front panel makes this controller compatible with hardwired installation by a licensed electrician. It can also be used in semi-permanent setups where the power feed is routed via a dedicated sub-panel breaker.
Usage Guidelines
The Helios 18 controls the timing and power delivery for up to twelve HID lights. These guidelines summarize how the controller functions in normal operation based on the manufacturer’s product description.
Splitting lights across two schedules: The dual trigger cords allow the 12 outlets to be divided between two timers. Typically, outlets 1–6 are wired to one trigger cord and outlets 7–12 to the second. Each trigger cord connects to a separate timer so the two groups can run different photoperiods independently. Check the included wiring diagram (available as an install guide from Titan Controls) for the exact outlet grouping for the Helios 18.
Load calculation: With 60 amps of output power at 240 V, the controller can theoretically carry 14,400 watts of continuous load. However, the listed maximum wattage is 12,000 W, which corresponds to twelve 1,000-watt HID ballasts. Do not exceed the 12,000 W or 60-amp output ratings. For rooms running twelve 600-watt ballasts (7,200 W total), the controller has ample headroom. NEC code generally requires circuits to be loaded no more than 80% of rated capacity — consult your electrician for the appropriate breaker sizing for your feed.
Input feed: The controller requires an 80-amp input service at 240 V. A licensed electrician should size the breaker and wire gauge for the input feed in accordance with local electrical code. The removable front panel provides access to the input terminals for this wiring.
Trigger cord connection: Plug each trigger cord into the corresponding port on the controller, then connect the opposite end of each cord to the switched output of your timer. When the timer switches on, it sends a signal through the trigger cord that activates the relay bank and turns on the connected lights.
How to Install the Titan Controls Helios 18
Installation requires a licensed electrician for the hardwired 240-volt input feed. The following steps reflect the general installation process for a hardwired HID lighting controller with trigger cord operation. Refer to the Titan Controls install diagram (SKU 702843 Application Diagram) for product-specific terminal assignments.
- Plan your power feed: Determine the breaker size needed for an 80-amp, 240-volt input. The electrician will size the wire gauge and breaker per NEC and local code. Identify the sub-panel or main panel circuit that will serve the controller.
- Mount the enclosure: Choose a wall location in or adjacent to the grow room. The steel enclosure should be mounted on a dry, non-combustible surface. Allow clearance on all sides for heat dissipation and access to the front panel.
- Remove the front panel: The front panel is removable to expose the terminal block for input wiring. Remove the fasteners on the front panel and set it aside before making any electrical connections.
- Land the input feed wires: With power off at the breaker panel, have your electrician connect the 240-volt input feed wires to the input terminals per the application diagram. Verify correct phasing and grounding before re-energizing.
- Replace the front panel: Once the input wiring is complete and verified, reattach the front panel. Confirm all fasteners are secure.
- Connect ballast power cords to outlets: Plug each HID ballast’s power cord into one of the twelve outlets. The universal outlets accept 120 V and 240 V cord types. Arrange ballast cords so they are not pinched or in contact with heat sources.
- Connect trigger cords to timers: Plug the first trigger cord into the first trigger input on the controller and into the timer that will govern lights on that group of outlets. Repeat for the second trigger cord if you are using two separate schedules.
- Test the system: Set your timers to a test on-cycle and verify that all lights in each group turn on and off as expected. Check for any unusual sounds from the relay bank during switching. If a relay chatters or fails to seat, consult Titan Controls technical support before operating the room.










Reviews