The TrolMaster DSP-2 is a 240V plug-and-play program device station (timer module) for use with the TrolMaster Hydro-X and Aqua-X climate and irrigation automation systems. It allows any device drawing up to 10A at 240V to be scheduled and controlled by time, run as a recycling irrigation timer, or wired as a master pump controller — all without additional wiring beyond the included RJ12 cables and T-splitter.
TrolMaster DSP-2 Specifications
The DSP-2 operates on universal voltage (100–240 VAC), making it compatible with both North American 120V and 240V power configurations. The table below lists the published electrical and physical specifications from the manufacturer.
| Specification | Value |
|---|---|
| Input Voltage | 100–240 VAC, 50/60 Hz |
| Output Voltage | 100–240 VAC, 50/60 Hz |
| Output Current | 10A maximum |
| Working Temperature | 32–122°F (0–50°C) |
| Working Humidity | ≤90% RH (non-condensing) |
| Package Dimensions | 85 mm (L) × 80 mm (W) × 90 mm (H) |
| Gross Weight (per pack) | 0.34 kg |
| Package Contents | 1× Device Station, 1× 16 ft RJ12 Cable, 1× 4 ft RJ12 Cable, 1× RJ12 T-Splitter |
Why Choose the TrolMaster DSP-2
The DSP-2 addresses a common gap in grow-room automation: connecting 240V load devices to an automated control system without running dedicated relay hardware or custom wiring. It slots into the TrolMaster bus via RJ12 and integrates directly with both the Hydro-X climate controller and the Aqua-X irrigation controller.
- Time-based control for any 240V device: Any load drawing 10A or less at 240V can be scheduled through the Hydro-X. This covers most pumps, supplemental heaters, CO₂ generators, and exhaust fans that run on 240V circuits.
- Flexible irrigation timer modes on Aqua-X: The DSP-2 can be programmed to trigger at specific times of day or night, or configured as a recycling timer. The recycling mode optionally accepts a maximum cycle count, which is useful for flood-and-drain tables and drip systems that need finite run windows.
- Master pump controller mode: When the DSP-2 is connected to the Aqua-X 24VAC module and a pump is plugged in, the station automatically activates the pump whenever any of the 24VAC irrigation zones fires. This removes the need for a separate pump relay in multi-zone irrigation builds.
- Plug-and-play installation: A 16 ft and a 4 ft RJ12 cable plus a T-splitter are included in the box. Daisy-chaining additional modules or splitting the bus does not require extra hardware purchases for most setups.
- Address assignment: Each DSP-2 unit carries an assignable address, so multiple stations can share the same controller bus without signal collision. This makes the module stackable as grow operations expand.
Best Uses for the TrolMaster DSP-2
The DSP-2 is most useful in cultivation environments where 240V devices need scheduled control that is tied to a central automation system rather than managed by standalone mechanical timers. The following scenarios represent its primary applications as described in the product documentation.
- Scheduled 240V lighting control on Hydro-X: Growers running 240V HID, CMH, or LED fixtures can connect them through the DSP-2 for time-based on/off control managed from the Hydro-X interface, consolidating light schedules with other climate parameters in one place. For comparison, if you are managing multiple devices including advanced dimming, the Autopilot PX2 Advanced Lighting Controller offers dedicated multi-zone lighting control.
- Irrigation timing on Aqua-X: Drip systems, flood-and-drain tables, and top-feed recirculating systems all benefit from the DSP-2’s recycling timer mode. Setting a maximum cycle count prevents over-watering during extended dark periods.
- Master pump integration in multi-zone irrigation: In a setup with several 24VAC solenoid zones, the DSP-2 eliminates the need for each zone to independently manage pump activation. The master pump controller mode activates whenever any zone is open, reducing hardware and simplifying wiring.
- CO₂ generator control: 240V CO₂ burners can be connected to the DSP-2 and scheduled around the light cycle via the Hydro-X, preventing CO₂ waste during dark periods without a separate analog timer.
- Supplemental heating on 240V circuits: Space heaters and radiant heating elements that draw under 10A at 240V can be put on a night-drop schedule through the DSP-2, linking heat management to the same platform controlling humidity and ventilation.
TrolMaster DSP-2 vs Similar Products
The DSP-2 occupies a specific position in the TrolMaster ecosystem: it is a bus-connected station, not a standalone digital timer. Understanding this distinction is important when evaluating whether it fits a given build.
A standalone digital timer or mechanical outlet timer can schedule 240V devices without any controller, but it operates independently — changes require physical access to the timer itself, and there is no integration with temperature, humidity, or irrigation logic. The DSP-2 delegates scheduling to the Hydro-X or Aqua-X, which means timer programs can be adjusted remotely (if a TrolMaster network module is present) and can be tied to sensor thresholds rather than clock time alone.
TrolMaster’s own 120V equivalent (the DSP-1) covers the same use cases but is limited to 120V devices. If a grow room uses exclusively 120V loads, the DSP-1 is sufficient. The DSP-2 is specifically for growers whose high-draw equipment — pumps, generators, larger HID fixtures — requires 240V power. It is not a replacement for a relay module or a contactors-based panel; loads above 10A at 240V will need a purpose-built relay or contactor instead.
Compatibility & Operating Range
The DSP-2 is designed specifically for the TrolMaster Hydro-X climate controller and the TrolMaster Aqua-X irrigation controller. It uses the same RJ12 bus architecture as other TrolMaster peripheral stations and requires one of those two controllers to function — it is not a standalone device and does not operate without a host controller on the bus.
Electrical compatibility: the station accepts 100–240 VAC input at 50 or 60 Hz, covering both North American 120V/240V grids and international 220–240V supplies. The output passes the same voltage and frequency at up to 10A continuous draw. This makes it compatible with most 240V cultivation equipment in the North American market, including:
- 240V HID ballasts and CMH drivers drawing under 10A
- Irrigation pumps and pressure pumps rated at 10A or below at 240V
- CO₂ generators with 240V power requirements within the 10A limit
- Supplemental resistance heaters within the 10A rating
Environmental operating range: 32–122°F (0–50°C) working temperature, up to 90% relative humidity (non-condensing). The station should not be placed in direct contact with standing water or inside a reservoir cabinet where condensation accumulates on electronics.
If you need precise humidity management alongside device scheduling, pairing the DSP-2 with dedicated humidity control equipment such as the Ideal-Air Pro Series dehumidifier condensate pump helps maintain the non-condensing environment the DSP-2 requires for reliable long-term operation.
Usage Guidelines
The DSP-2 supports three distinct operating modes, each configured through the host controller’s interface. Before selecting a mode, confirm which controller the DSP-2 is connected to (Hydro-X or Aqua-X), as available settings differ between the two platforms.
Time-based scheduling mode (Hydro-X): Set the on-time and off-time in the Hydro-X schedule menu for the DSP-2 channel. The device connected to the outlet will power on and off at the configured times each day. This mode works for lighting, supplemental heating, and CO₂ generators that follow a fixed daily cycle. Assign a unique bus address to the station before programming to avoid conflicts if multiple DSP units are connected to the same controller.
Irrigation timer and recycling timer mode (Aqua-X): Configure the DSP-2 channel in the Aqua-X to trigger at a specific time window (start time and duration), or enable recycling timer mode for interval-based irrigation. In recycling mode, set the run duration and the rest interval. Optionally, enter a maximum number of cycles per day to cap total irrigation time during a single light or dark period.
Master pump controller mode (Aqua-X with 24VAC module): When the DSP-2 is designated as the master pump channel in the Aqua-X configuration and the 24VAC module is present on the bus, the station monitors zone valve activity. The pump outlet activates automatically when any zone opens and deactivates once all zones close. No additional timer configuration is required for the pump in this mode.
Load limits: Do not connect devices that draw more than 10A at 240V. Exceeding the output current rating risks outlet damage and may void manufacturer support. Verify the rated current draw of the connected device before energizing the circuit. Most 240V grow-room loads are rated in watts — divide watts by 240 to calculate amperage (for example, a 2,000W HID ballast draws approximately 8.3A at 240V, which is within the DSP-2’s 10A rating).
How to Install the TrolMaster DSP-2
Installation requires a working TrolMaster Hydro-X or Aqua-X controller already set up and powered. No tools are required beyond what is included in the package.
- Assign an address: Before connecting to the controller bus, set the address jumper or DIP switch on the DSP-2 to an unused station address. Consult the Hydro-X or Aqua-X manual for the available address range and any addresses already in use on the bus.
- Connect the RJ12 cable: Plug one end of the included 16 ft RJ12 cable into the DSP-2’s RJ12 socket and the other end into an available port on the controller or an existing T-splitter on the bus. If running to a distant location in the grow room, use the 16 ft cable for main routing; use the 4 ft cable for short local drops or to bridge a T-splitter to the station.
- Use the T-splitter to expand the bus (if needed): If another station is already using the nearest controller port, insert the included RJ12 T-splitter into that port. Plug the existing station cable into one side of the T-splitter and the DSP-2’s cable into the other side. This daisy-chains the stations without requiring an additional port on the controller.
- Connect the load device: Plug the 240V device (pump, ballast, heater, etc.) into the DSP-2 outlet. Confirm the device’s current draw is within the 10A rating before powering on.
- Power on and verify the LED indicator: Apply power to the controller and the DSP-2. The LED indicator on the station should illuminate to confirm the module is active and communicating with the controller. If the LED does not light, check the RJ12 connections and confirm the station address is correctly set.
- Configure the operating mode in the controller: Navigate to the DSP-2 channel in the Hydro-X or Aqua-X menu. Select the desired mode (time-based schedule, recycling timer, or master pump controller) and enter the timing parameters as described in the Usage Guidelines section above.
- Test the output: Manually trigger the DSP-2 channel from the controller interface (using the test or manual override function if available) to confirm the connected device powers on and off correctly before relying on the automated schedule.