The TrolMaster DST-1 Temp Device Station is a temperature control relay module for the Hydro-X environmental controller. It lets growers connect and automate any standard heating or cooling device — heaters, air conditioners, fan heaters — through the Hydro-X system. The module accepts 100–240 VAC input at 50/60 Hz and handles loads up to 10 amps, covering a wide range of equipment used in both residential and commercial grow facilities.
TrolMaster Hydro-X Temp Device Station Specifications
Specifications are sourced from the canonical product data and manufacturer documentation for model DST-1.
| Specification | Value |
|---|---|
| Brand | TrolMaster |
| Model Number | DST-1 |
| Input Voltage Range | 100–240 VAC |
| Frequency | 50/60 Hz |
| Maximum Load Current | 10 A |
| Weight | ~2 lb (1.9996 lb) |
| Compatible Controller | TrolMaster Hydro-X |
Why Choose the TrolMaster Hydro-X Temp Device Station
The DST-1 is designed for growers who want automated temperature control without replacing existing heating or cooling equipment. A few reasons it fits that use case:
- Works with existing equipment. The DST-1 connects to heating or cooling devices you already own — space heaters, portable air conditioners, fan-coil units — rather than requiring proprietary hardware. If the device runs on standard AC power and draws 10 amps or less, it can be controlled through this module.
- World voltage range (100–240 VAC, 50/60 Hz). The module operates across the full international voltage range, so it functions in both North American 120V setups and European or commercial 240V facilities without a separate transformer or adapter.
- Integrates with the Hydro-X ecosystem. The DST-1 connects directly to a TrolMaster Hydro-X controller, which means temperature schedules, setpoints, and alarms are managed from the same interface used for humidity, CO2, and lighting. No separate app or controller is needed.
- 10-amp capacity covers most grow-room devices. Most portable heaters and compact air conditioners used in grow rooms draw 8–10 amps at 120V. The 10A rating handles typical devices in that range without the need for additional relay hardware.
Best Uses for the TrolMaster Hydro-X Temp Device Station
The DST-1 is suited to growers running a Hydro-X system who want to bring temperature-controlled devices under unified automation. Typical applications include:
- Automating a portable heater in a tent or small room. Connect a space heater to the DST-1 and set heating setpoints in the Hydro-X — the controller cycles the heater on and off to hold target temperature without manual intervention.
- Controlling a portable air conditioner or window unit. A portable AC pulling under 10 amps can be routed through the DST-1, letting the Hydro-X cool the room on a schedule or in response to temperature sensor readings.
- Multi-zone grow facilities using Hydro-X. In facilities with multiple rooms each running a Hydro-X unit, one DST-1 per room gives each zone its own temperature automation without a dedicated thermostat at each location.
- Facilities on international voltage standards. Growers outside North America or in facilities wired for 208–240V can use the DST-1 without sourcing a different relay module — the 100–240V range covers both common standards.
- Retrofit builds where the main HVAC is not directly controllable. If the primary HVAC cannot accept a direct control signal, a supplemental heater or cooler plugged into the DST-1 can handle fine-tuning while the main system handles baseline conditioning.
Compatibility & Operating Range
The DST-1 is a module for the TrolMaster Hydro-X environmental controller platform. It is not a standalone thermostat — it requires a Hydro-X controller to function. The module plugs into the Hydro-X via the designated device station port and receives control signals from the Hydro-X logic.
On the load side, the module supports any single-phase heating or cooling device rated for 100–240 VAC at 50 or 60 Hz, up to 10 amps. This covers the majority of portable grow-room heaters and compact air conditioners. Devices with compressor start-up draw significantly above 10A (some larger window units) may not be suitable — check your device’s nameplate amperage and startup surge rating before connecting.
If you’re pairing the DST-1 with other Climate & Environment accessories, the Autopilot PX2 Advanced Lighting Controller is a complementary tool for managing lighting schedules alongside temperature, and the Active Air HD Pedestal Fan can be used to improve air circulation in spaces where the DST-1 is managing a heater or cooler.
Usage Guidelines
The DST-1 operates as a switched outlet controlled by the Hydro-X. The Hydro-X monitors temperature via its sensor and activates or deactivates the DST-1 output based on your configured setpoints. Standard practice:
- Set a heating setpoint (low threshold) — the Hydro-X turns the heater on when temperature drops below this point and turns it off when temperature recovers.
- Set a cooling setpoint (high threshold) — the Hydro-X turns the cooling device on when temperature exceeds this point and turns it off once temperature returns to range.
- Do not exceed the 10A maximum load. Verify your device’s running amperage (not just startup draw) before use.
- The module supports the world voltage range but always verify your wall outlet voltage matches your connected device’s rating — the DST-1 does not convert voltage, it switches the supply.